| OM180 | ||
| Flow Rate/Temperature Rise: | 6.2 gal/min (40°F rise), 5.0 gal/min (50°F rise) 4.1 gal/min (60°F rise), 3.5 gal/min (70°F rise) 3.1 gal/min (80°F rise) |
|
| Ignition | High Voltage Discharge Spark | |
| Efficiency | 87.1% AFUE rating | |
| Fuel Consumption: | 1.05 gal/hr | |
| Capacity of Heat Exchanger | 5.10 gal | |
| Temperature Differential Settings | 3.6°F, 18°F, 36°F (3 settings by selector switch) | |
| Fuel System | External Tank*** | |
| Dimensions (W x H x D): | 12-5/8" x 27-3/4" x 22-1/2" | |
| Weight: | 81 lbs. empty | |
| Vent Pipe Hole: | 4-3/4" diameter (for flue pipe installation kit) | |
| Maximum Length of Vent Pipe System: | 10 ft., 3 bends or less (exhaust pipes for flue pipe installation kit) | |
| Electrical Rating: | 120 Volts AC, 60 Hz Ignition - 120W Burning - 98W |
|
| Fuel Type | ASTM D3699 K1 KEROSENE ASTM D396 NO.1 FUEL OIL ASTM D975 ULTRA LOW SULPHUR DEISEL (ULSD) ASTM D396 No.2 Fuel OIL (HOME HEATING OIL) | |
| Required Accessories: | Flue Pipe Installation Kit or 5-inch Chimney Adapter Kit Fuel Filter and Drain Valve | |
| Safety Device | High Limit Thermistor Heat Exchanger Bi-metal Switch Temperature Fuse, Fusible Link Valve Exhaust Air Temperature: less than 500°F Temp & Pressure Relief Valve (included) | |
| Nozzle Size | 0.85 GPH | |
| Spraying Angle | 60 degrees F | |
| Spray Pattern | Delavan Type XA | |
| Temperature Fuse | 282 degree F | |
| Electric Current Fuse | 5 A (Main Control) 7 A (Auxiliary Port for Circulation Pump., etc.) | |
| Optional Accessories | Remote Controller |